Low Humidity, Low Temperature, Constant Temperature / Humidity Chamber

VL -20~+60ºC

NAME

Silvery Emperor VL series

MODEL

SE-23VL-A

SE-24VL-A

SE-25VL-A

SE-27VL-A

Classification

High molecule thin film humidity sensor type

POWER SUPPLY

3φ AC200V±10% 50/60Hz

POWER REQUIRED

20.9A

23.9A

24.6A

35.0A

CONTROL SYSTEM

Relative Temperature/Humidity control system (R.T.H.C.system)

OPERATING CONDITIONS

Ambient: 0.0~35.0ºC, 20~80%RH

PERFORMANCE

 

Temp./Hunid. range

-20.0~60.0ºC / 5~80%RH

Stability

±0.3ºC / ±2.5%RH

Uniformity

±1.0ºC at -20.0~20.0ºC, ±1.0ºC・3.0%RH at 20.1~60.0ºC

Temperature rise time

-20.0→60.0ºC within 90 min.

Temperature fall time

20.0→-20.0ºC within 60 min.

Lowest temperature

-20.0ºC

CONFIGURATION

 

Controller

KATO TX instrumentation

Internal material

SUS-304 grinding finished stainless steel plate

External material

SUS-430 Hair line finished stainless steel plate

Insulating material

Glass wool

DEHUMIDIFYING SYSTEM

Unified condensing refrigerating system, Air cooling or water cooling type

Refrigerator

Complete closed type compressor

Out put

0.75Kw

0.75Kw

1.1Kw

1.1Kw

Power ability changing

Multi step automatic switching system by micro computer control

Cooling coil

Plate fin cooler : Corrosion preventing coating finished

DRY HEATER

Sheath heater

WET HEATER

Copper chrome-plated plug heater

BLOWER FAN

Sirocco fan

DEHUMIDFIER

Silica gel rotor  chemical dehumidifier and Pre-cooler

ACCESSORIES

Observation window with heater on both sides, Cable hole 30φ ×1pc.

Free settable shelf ×2 sets, Halogen room lamp,

Integrating meter on TX display,  Caster, Adjuster,

Power cable for only model: SE-23, 24, 25 (3.5m)

SAFETY UNITS

Leak breaker, Refrigerator overload relay, Blowing motor overload relay,

Boiling without water prevention unit, Reverse phase prevention relay,

Overload and short circuit protector for SSR,

Overload and short circuit protecting fuse for operating circuit,

Water pressure switch for water cooling type, Trouble monitor on TX display,

Alarm of temperature up/low limit error, Burn out circuit,

 Overheat prevention unit,  efrigerator pressure switch

WATER SUPPLYING SYSTEM

Selectable from 2 methods;
Water tank with natural gravitation method or Supply from waterworks

Water tank

fixed tank on the chamber 1 set

OPTIONS

Various Recorder, Cable hole: 30, 50, 100φ, Shelf, Water tank for humidifier,

Operation holes, Defroster, Excessive cooling preventive unit, Recording paper,

Room lamp:Halogen bulb, Interface RS-232C/GP-IB,

See through door, Deionizer for humidifying water, Time signal unit, Exhaust duct

INTERNAL CAPACITY (litter)

175

288

441

800

DIMENSIONS

 

 

 

 

INTERNAL (W×H×Dmm)

 500× 700× 500

 600× 800× 600

 700× 900× 700

1000×1000× 800

EXTERNAL (W×H×Dmm)

1790×1650× 950

1890×1650×1050

1990×1750×1150

2290×1910×1250

WEIGHT  (kg)

380

440

470

670

 

*Concerning the temperature uniformity performance, according to the Standard for the Performance of Humidity Chambers (JTM K-03) of Testing Machinery Association of Japan, the classes are organized according to a measured numerical value which is indicated by the distance from each of the wall surface to a relative wall surface that excludes 1/6 of the space.

*The temperature rising and falling performance is at an ambient temperature of 20°C, or with a cooling water temperature of 25°C when the chamber is in an unloaded condition.

*Humidifying water quality should be PH 6.0~7.2, electrical conducting rate is less than 20μS/cm.

*The classification of the air cooling or water cooling type is carried out using the A (air cooling) or W (water cooling) at the end of the model number.

*The above specifications may be changed for any improvement of product without giving any preliminary notification.