元に戻るホームページへ戻る

Rapid Heating and Cooling, Low Temperature, Constant Temperature Chamber

ML dry -70~+180ºC

NAME

Silvery Prince ML series

MODEL

SSP-75ML-A

SSP-75ML-W

 

Air cooling type

Water cooling type

POWER SUPPLY

3φ AC200V±10% 50/60Hz

POWER REQUIRED

24KVA, 100A

CONTROL SYSTEM

Relative Temperature control system (R.T.C.system)

OPERATING CONDITIONS

Ambient: 0.0~35.0ºC, 20~80%RH

PERFORMANCE

 

Temperature range

-70.0~180.0ºC

Stability

±0.3ºC

Uniformity

±1.0ºC at -70.0~20.0ºC, ±1.0ºC at 20.0~95.0ºC, ±1.5ºC at 95.1~150.0ºC, ±2.0ºC at 150.1~180.0ºC

Temperature rise time

-70.0→180.0ºC within 90 min. at refrigerator OFF

Temperature fall time

20.0→-70.0ºC within 90 min.

Lowest temperature

-70.0ºC

CONFIGURATION

 

Controller

KATO TX instrumentation

Internal material

SUS-304 grinding finished stainless steel plate

External material

SUS-430 Hair line finished stainless steel plate

Insulating material

Glass wool

REFRIGERATING SYSTEM

Dual condensing refrigerating system

Air cooling type

Dual condensing refrigerating system

Water cooling type

Refrigerator

Complete closed type compressor

Out put

5.5Kw / 7.5Kw

5.5Kw / 7.5Kw

Power ability changing

Multi step automatic switching system by micro computer control

Cooling coil

Plate fin cooler : Corrosion preventing coating finished

DRY HEATER

Sheath heater, Nichrome wire heater

BLOWER FAN

Sirocco fan

ACCESSORIES

Observation window with heater on one side, Cable hole 50φ ×4pc.

Free settable shelf ×2 sets, Halogen room lamp,

Integrating meter on TX display, Caster, Adjuster

SAFETY UNITS

Leak breaker, Refrigerator overload relay, Blowing motor overload relay,

Reverse phase prevention relay, Overload and short circuit protector for SSR,

Overload and short circuit protecting fuse for operating circuit,

Water pressure switch for water cooling type, Trouble monitor on TX display,

Alarm of temperature up/low limit error, Burn out circuit,

Overheat prevention unit, Refrigerator pressure switch

OPTIONS

Various Recorder, Cable hole: 30, 50, 100φ, Shelf, Operation holes,

Defroster, Excessive cooling preventive unit, Recording paper,

Room lamp:Halogen bulb, Interface RS-232C/GP-IB, Time signal unit, Exhaust duct

INTERNAL CAPACITY (litter)

441

INTERNAL DIMENSIONS

W 700×H 900×D 700mm

EXTERNAL DIMENSIONS

W1405×H1965×D 1975mm

WEIGHT  (kg)

1100

 

*Concerning the temperature uniformity performance, according to the Standard for the Performance of Humidity Chambers (JTM K-03) of Testing Machinery Association of Japan, the classes are organized according to a measured numerical value which is indicated by the distance from each of the wall surface to a relative wall surface that excludes 1/6 of the space.

*The temperature rising and falling performance is at an ambient temperature of 20°C, or with a cooling water temperature of 25°C when the chamber is in an unloaded condition.

*The above specifications may be changed for any improvement of product without giving any preliminary notification.